SIMFY Custom Sourcing
UKCA vs CE Marking for Construction Products in 2026
CE marking is now accepted in Britain indefinitely. What SI 2025/1172 changed, why UKCA is optional, and what evidence a buyer should ask for instead.
European buyers rarely argue about product quality first. They ask for a document, and the conversation ends there if it is missing.
What Europe asks for
A construction product covered by a harmonised European standard carries CE marking and is supplied with a Declaration of Performance, which states the exact classes the product achieved when tested by a notified body. Fire performance is stated as an EN 13501 class. The rules are being updated under a long transition, so confirm the current requirement for your product.
| What applies | CE marking under the European construction products rules |
|---|---|
| What you receive | A Declaration of Performance (DoP) |
| Who tests | A notified body listed by the EU |
| Fire classification | EN 13501, for example A1, A2-s1,d0, B-s1,d0 |
| Note | The rules are under a long transition. Confirm the current position. |
A CE mark on packaging proves nothing on its own.
Fire resistant means nothing. A2-s1,d0 means something.
Change the substrate and the classification may not carry over.
Tell us what you need for Europe or see every market we ship to.
AfricaKenya · Ghana · Nigeria · Tanzania · Uganda · Côte d'Ivoire · South Africa · Africa
Europe and the UKUnited Kingdom · Germany · Netherlands · Belgium · Poland · Ireland · Europe
AmericasUnited States · Americas

SIMFY Custom Sourcing
CE marking is now accepted in Britain indefinitely. What SI 2025/1172 changed, why UKCA is optional, and what evidence a buyer should ask for instead.

SIMFY FIRESYS
What A2-s1,d0 actually means. The EN 13501-1 classes A1 to F, the smoke and droplet codes, the fl and L subscripts, and how to check a…

SIMFY FIRESYS
Sourcing fire dampers? Why EN 1366-2 is a test method and EN 15650 the product standard, what ve, ho and S mean, and what the enquiry…

SIMFY AFROBUILD
Specifying architectural glass? Why toughened panes break on their own, what heat soaking really removes, and which EN product standard applies to each route.

SIMFY AFROBUILD
Sourcing fire rated doors? What EN 1634-1 tests, what E, I, W, Sa, S200 and C0-C5 mean, and why leaf, frame, seals and closer must be…

SIMFY FIRESYS
Buying intumescent coating for a steel frame? How section factor, critical temperature and EN 13381-8 tables decide thickness, and what to send before quoting.

SIMFY FIRESYS
Sourcing fire collars for a project? What EN 1366-3 really tests, why U/U and U/C decide whether your certificate applies, and what to check before ordering.

SIMFY Custom Sourcing
About to pay a new supplier? How to verify a supplier properly: the registration check, what a factory audit sees, and the statistical limit of inspection.

SIMFY Custom Sourcing
Buying from overseas? FOB vs CIF vs DDP explained: where risk really transfers, why FOB fails for containers, and when DDP is not legally available at…

SIMFY FIRESYS
A firestop specification fails when it names a product instead of a performance. How to write the classification, evidence and substitution clauses properly.